BSVWQ - RED CELL TAGGING KIT

  • MSDS: BSVWQ
  • Manufacturer: MALLINCKRODT
  • Product Name: RED CELL TAGGING KIT
  • National Stock Number: 6505-00N046725
Product Identification

Product ID:RED CELL TAGGING KIT
MSDS Date:01/01/1993
FSC:6505
NIIN:00N046725
MSDS Number: BSVWQ

Responsible Party
MALLINCKRODT
2703 WAGNER PLACE
MARYLAND HEIGHTS, MO 63043
US

Emergency Phone: 314-344-3800

Info Phone: 314-344-3800

Cage: ZA916

Contractor
MALLINCKRODT MEDICAL, INC
M MARYLAND HEIGHTS, MO 63043 US

Telephone: 314-770-7800

Cage: ZA916

Ingredients

RADIOACTIVE CHROMIUM

CAS: 10039-53-9

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL:DOES NOT EASILY BECOME
AIRBORNE. NOT EXPECTED TO BE HEALTH HAZARD VIA INHAL. INGEST:MAY
CAUSE ASYMPTOMATIC PHYSIOLOGICAL UPTAKE BY SPECIFIC TARGET
ORGANS/TISSUES. SKIN: NOT EXPECTED TO PR ODUCE ANY ACUTE ADVERSE
HEALTH EFFECTS.EYES:NO ADVERSE EFFECT EXPECTED BUT MAY CAUSE
MECHANICAL (EFTS OF OVEREXP)
Explanation of Carcinogenicity:CHROMIUM:IARC MONOGRAPHS, VOL 49, PG 49,
1990:GROUP 1. NTP 6TH ANNUAL RPT ON CARCIN, 1991:KNOWN TO BE
CARCIN. (SUPDAT)
Effects of Overexposure:HLTH HAZ:IRRITATION. CHRONIC: THE HEALTH RISKS
ASSOCIATED WITH CHRONIC RADIATION EXPOSURE (CANCER, LEUKEMIA,
GENETIC & TERATOGENIC EFFECTS) ARE BELIEVED TO INVOLVE LEVELS OF
RADIATION EXPOSURE WHICH A RE MUCH HIGHER THAN THOSE PERMITTED
OCCUPATIONALLY.
Medical Cond Aggravated by Exposure:NO INFORMATION FOUND.

First Aid

First Aid:INHAL:REMOVE TO FRESH AIR. SUPPORT BRTHG (GIVE O2/ARTF RESP).
INGEST:NOTIFY RADIA SFTY PERS IMMED. AMT OF MATL INGESTED SHOULD BE
ASSESSED & DOCUMENTED. SKIN:WASH THORO W/SOAP & WATER UNTIL NO M
ORE RADIOACTIVITY CAN BE REMOVED. ALWAYS BLOT DRY. DO NOT ABRADE
SKIN. NOTIFY RADIA SFTY PERS. EYES:WASH W/WATER FOR @ LEAST 15 MIN/
UNTIL NO MORE RADIOACTIVITY CAN BE REMOVED. NOTIFY RADIA SFTY PERS

Fire Fighting

Extinguishing Media:USE ANY MEANS SUITABLE FOR EXTINGUISHING
SURROUNDING FIRE.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NOT CONSIDERED TO BE A FIRE/EXPLOSION
HAZARD.

Accidental Release

Spill Release Procedures:IF PROD RECEIVED IN LEAKING CNDTN/ANY LOSS/
RELS OF RADIOACTIVE CONTENTS OCCURS, NOTIFY RADIA SFTY DEPARTMENT &
MFR @ (314)344-3800. ALL CLEANUP OPERATIONS SHOULD BE PERFORMED
ACCD TO STD OPERATING PR OC (SOPS) ESTABLISHED BY RADIA SFTY
OFFICER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE @ 15C TO 30C. HNDLG TIME SHOULD
BE KEPT TO MIN & APPROP SHIELDING SHOULD BE USED. HNDLG DEVICES
SUCH AS SYRINGE SHIELDS & TONGS SHOULD BE USED.
Other Precautions:STORAGE & DISPOSAL OF PRODUCT SHOULD BE CONTROLLED IN
A MANNER WHICH IS IN COMPLIANCE WITH THE APPROPRIATE REGULATIONS OF
THE FEDERAL OR STATE GOVERNMENT AGENCY AUTHORIZED TO LICENSE THE
USE OF THIS R ADIONUCLIDE.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN . NOT EXPECTED TO REQUIRE PERSONAL
RESPIRATOR USAGE.
Ventilation:PROPERLY SEALED CONTAINERS ARE NOT EXPECTED TO REQUIRE ANY
SPECIAL VENTILATION.
Protective Gloves:DISPOSABLE PLASTIC, LATEX/RUBBER GLOVES.
Eye Protection:ANSI APPROVED SAFETY GLASSES .
Other Protective Equipment:LABCOAT.
Work Hygienic Practices:NO SMOKING, EATING OR DRINKING SHOULD BE
ALLOWED IN ANY AREA WHERE RADIOACTIVE MATERIALS ARE HANDLED OR
STORED.
Supplemental Safety and Health
EXPLAN OF CARCIN:HUMAN/ANIMAL:LUNG CANCER, SKIN ULCERS.

Chemical Properties

HCC:A2
Boiling Pt:B.P. Text:212F,100C
Melt/Freeze Pt:M.P/F.P Text:32.0F,0.0C
Solubility in Water:SOLUBLE
Appearance and Odor:CLEAR, SLIGHTLY YELLOW SOLUTION IN A 2.5 ML GLASS
VIAL; ODORLESS.

Stability

Stability Indicator/Materials to Avoid:YES
NO INFORMATION FOUND.
Stability Condition to Avoid:STABLE UNDER ORDINARY CONDITIONS OF USE
AND STORAGE.
Hazardous Decomposition Products:MAY EMIT RADIOACTIVE FUMES CONTAINING
CR-51 WHEN HEATED TO DECOMPOSITION.

Disposal

Waste Disposal Methods:ENSURE COMPLIANCE WITH LOCAL, STATE & FEDERAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.